Stramit Lo-Clad
Specifications
Features
- 820mm Cover – to maximise efficiency and reduce costs.
- Easy Fixing – conventional through fixed screws maximise performance and installation.
- Low Rib Height – for smart, neat appearance. Used effectively in minimal dust zones, eg: health applications.
- Versatility – suitable for many applications – garage doors, soffits, fascias and general wall cladding requirements.
Applications
Stramit Lo-Clad™wall sheeting is an economical but attractive cladding for both industrial and some domestic applications. The low profile makes it effective in soffits and fascias as well as walling.
Materials
Stramit Lo-Clad™ wall sheeting is a cold roll formed wall cladding. Steel product is 0.42mm G550 base material (550 MPa minimum yield stress).
| |||||||||||||||
Note: This product is not available in South Australia
Design
Pressures
| STRAMIT LO-CLAD™ WALL SHEETING – SERVICEABILITY LIMIT STATE CAPACITY | |||||||||
| span type | pressure (kPa) at the spans (mm) shown | ||||||||
| 600 | 900 | 1200 | 1500 | 1800 | 2100 | 2400 | |||
| internal | 6.43 | 3.47 | 2.17 | 1.44 | 0.98 | 0.66 | 0.42 | ||
| equal | 6.43 | 3.47 | 2.17 | 1.44 | 0.98 | 0.66 | 0.42 | ||
| double | 6.65 | 3.59 | 2.24 | 1.49 | 1.01 | 0.68 | 0.44 | ||
Impact
For wall areas likely to be subject to human impact, sheeting spans should be reduced. Impact loads will vary considerably and these are not prescribed in Australian Standards. A maximum span of 1000m is suggested for such areas, but this should be adjusted dependent upon the exposure and importance of the application.
Note: This product is not available in South Australia
Installation
Fasteners
All fastening screws must conform to AS3566 – Class 3. They are to be hexagon headed and, for water resistant applications, must be used with sealing washers.
Pan-fix to girts top hats or stud using:
For steel (0.75bmt or greater)
– No.10 x 16mm self-drilling and threading screws.
For timber (F11 or better)
– No. 10 x 25mm type 17 screws.
Side Laps
– No. 8 x 12mm ‘S’ point screws or,
– 3.2mm diameter sealed aluminium pop rivets.
Fastener Positions
Fix adjacent to the overlap and each subsequent rib (5 fasteners per sheet) at every support. Spans over 1000mm require the sidelaps to be stitched at mid-span. For further installation information see the section later in this manual.
![]()
Availability
Product Availability
|
Y - Yes N - No S - Subject to project size